Home » Shop » DC/DC » Isolated » DIP Package » Brick Package » HAE100W

HAE100W

Output: 100W Datasheet

FEATURES
• NO MINIMUM LOAD REQUIRED
• 3000VAC REINFORCED INSULATION FOR 110VIN 2250VDC BASIC INSULATION FOR 24VIN AND 48VIN
• UL60950-1, EN60950-1, IEC60950-1, & EN50155 SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH

APPLICATIONS
• RAILWAY SYSTEM
• WIRELESS NETWORK
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• DISTRIBUTED POWER ARCHITECTURES
• SEMICONDUCTOR EQUIPMENT

TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25℃ otherwise noted
Model

Number

Input Range Output Voltage Output Current

@Full Load

Input Current

@ No Load

Efficiency Maximum

Capacitor Load

VDC VDC A mA % μF
HAE100-24S3P3W 9 ~ 36 3.3 25 20 91 75700
HAE100-24S05W 9 ~ 36 5 20 25 93 40000
HAE100-24S12W 8.5 ~ 36 12 8.4 25 90 7000
HAE100-24S15W 8.5 ~ 36 15 6.7 25 91 4460
HAE100-24S24W 8.5 ~ 36 24 4.2 25 90 1750
HAE100-24S28W 8.5 ~ 36 28 3.6 25 90 1280
HAE100-24S48W 8.5 ~ 36 48 2.1 35 90 430
HAE100-48S3P3W 16.5 ~ 75 3.3 25 15 91 75700
HAE100-48S05W 16.5 ~ 75 5 20 15 93 40000
HAE100-48S12W 16.5 ~ 75 12 8.4 20 90 7000
HAE100-48S15W 16.5 ~ 75 15 6.7 20 91 4460
HAE100-48S24W 16.5 ~ 75 24 4.2 20 90 1750
HAE100-48S28W 16.5 ~ 75 28 3.6 20 92 1280
HAE100-48S48W 16.5 ~ 75 48 2.1 25 91 430
HAE100-110S3P3W 43 ~ 160 3.3 25 10 87 75700
HAE100-110S05W 43 ~ 160 5 20 10 90 40000
HAE100-110S12W 43 ~ 160 12 8.4 10 90 7000
HAE100-110S15W 43 ~ 160 15 6.7 10 90 4460
HAE100-110S24W 43 ~ 160 24 4.2 10 90 1750
HAE100-110S28W 43 ~ 160 28 3.6 10 90 1280
HAE100-110S48W 43 ~ 160 48 2.1 10 91 430